@@ -32,7 +32,9 @@ at least want to alter the installation location.
|
|
|
|
|
|
If you are using a different system, or want to alter the default configuration, first run "make
|
|
|
mconfig" to generate the "mconfig" file which contains the build configuration. You can then edit
|
|
|
-this file by hand, before proceeding with the build.
|
|
|
+this file by hand, before proceeding with the build. Note that the the generated "mconfig" may be
|
|
|
+a symbolic link to a system-specific default config file. It is not necessary to edit the file; you
|
|
|
+can override variables on the "make" command line if you prefer.
|
|
|
|
|
|
An alternative to "make mconfig" is to use the provided "configure" script. It will try to
|
|
|
generate a suitable "mconfig" file, based on sensible defaults and options provided on the command
|
|
@@ -44,7 +46,33 @@ For more information on available options from the configure script, run:
|
|
|
|
|
|
You can also create and edit the "mconfig" file completely by hand (or start by copying one for a
|
|
|
particular OS from the "configs" directory) to choose appropriate values for the configuration
|
|
|
-variables defined within. In particular:
|
|
|
+variables defined within.
|
|
|
+
|
|
|
+
|
|
|
+Main build variables
|
|
|
+=-=-=-=-=-=-=-=-=-=-
|
|
|
+
|
|
|
+There are some build variables that may typically require adjustment. In particular, some
|
|
|
+variables control installation paths or paths that are used at runtime; they are:
|
|
|
+
|
|
|
+ SBINDIR : set to the directory where the executable files should be installed
|
|
|
+ MANDIR : set to the directory where manual pages should be installed
|
|
|
+ SYSCONTROLSOCKET : set to the default location of the control socket when Dinit is run as a system
|
|
|
+ manager (as opposed to a user service manager)
|
|
|
+
|
|
|
+Some variables affect whether the "shutdown" utility is included and how it is named:
|
|
|
+
|
|
|
+ BUILD_SHUTDOWN : (yes|no)
|
|
|
+ Whether to build the "shutdown" (and "halt" etc) utilities. These are only useful
|
|
|
+ if dinit is the system init (i.e. the PID 1 process). You probably don't want this
|
|
|
+ unless building for Linux as shutdown is not supported on other systems (yet).
|
|
|
+ SHUTDOWN_PREFIX :
|
|
|
+ Name prefix for "shutdown", "halt" and "reboot" commands (if they are built). This affects
|
|
|
+ both the output, and what command dinit will execute as part of system shutdown.
|
|
|
+ If you want to install Dinit alongside another init system with its own shutdown/halt/reboot
|
|
|
+ commands, set this (for eg. to "dinit-").
|
|
|
+
|
|
|
+The following variables affect compilation and link options:
|
|
|
|
|
|
CXX : should be set to the name of the C++ compiler (and link driver)
|
|
|
CXXFLAGS : are options passed to the compiler during compilation
|
|
@@ -58,20 +86,24 @@ For convenience, generated configuration also allows setting the following:
|
|
|
|
|
|
LDFLAGS_BASE : any link options that should be used by default for linking (including tests),
|
|
|
if LDFLAGS is not overridden, to which CXXFLAGS will be added if the
|
|
|
- configuration enables link-time optimisation (LTO). This provides a simple way to
|
|
|
- change only link options not relevant to LTO, without having to override the
|
|
|
- values for both LDFLAGS and TEST_LDFLAGS.
|
|
|
+ configuration enables link-time optimisation (LTO). Will be ignored if LDFLAGS
|
|
|
+ is set.
|
|
|
TEST_LDFLAGS_BASE : as LDFLAGS_BASE but for tests. The default is to use the same value (if any)
|
|
|
- as specified for LDFLAGS_BASE.
|
|
|
+ as specified for LDFLAGS_BASE. Ignored if TEST_LDFLAGS is set.
|
|
|
|
|
|
-Additionally, for cross-compilation, the following can be specified:
|
|
|
+Together, LDFLAGS_BASE and TEST_LDFLAGS_BASE provide a simple way to adjust link options without
|
|
|
+interfering with link-time optimisation (LTO). With LTO enabled, LDFLAGS must usually include the
|
|
|
+same options used for compilation; by adjusting LDFLAGS_BASE instead, you do not have to
|
|
|
+specifically include the compilation options as they will be included in LDFLAGS automatically.
|
|
|
+
|
|
|
+For cross-compilation, the following can be specified:
|
|
|
|
|
|
CXX_FOR_BUILD : C++ compiler for compiling code to run on the build host
|
|
|
CXXFLAGS_FOR_BUILD : any options for compiling code to run on the build host
|
|
|
CPPFLAGS_FOR_BUILD : any preprocessor options for code to run on the build host
|
|
|
LDFLAGS_FOR_BUILD : any options for linking code to run on the build host
|
|
|
|
|
|
-Note that the "eg++" or "clang++" package must be installed on OpenBSD as the default "g++"
|
|
|
+Note that the "eg++" or "clang++" package may need to be installed on OpenBSD if the default "g++"
|
|
|
compiler is too old. Clang is part of the base system in recent releases.
|
|
|
|
|
|
Then, from the top-level directory, run "make" (or "gmake" if the system make is not GNU make,
|
|
@@ -121,21 +153,6 @@ Other configuration variables
|
|
|
|
|
|
There are a number of other variables you can set in the mconfig file which affect the build:
|
|
|
|
|
|
-SBINDIR=...
|
|
|
- Where the "/sbin" directory is. Executables will be installed here.
|
|
|
-MANDIR=...
|
|
|
- Where the "man" directory is. Man pages will be installed here.
|
|
|
-SYSCONTROLSOCKET=...
|
|
|
- Default full path to the control socket, for when Dinit runs as system service manager.
|
|
|
-BUILD_SHUTDOWN=yes|no
|
|
|
- Whether to build the "shutdown" (and "halt" etc) utilities. These are only useful
|
|
|
- if dinit is the system init (i.e. the PID 1 process). You probably don't want this
|
|
|
- unless building for Linux.
|
|
|
-SHUTDOWN_PREFIX=...
|
|
|
- Name prefix for "shutdown", "halt" and "reboot" commands (if they are built). This affects
|
|
|
- both the output, and what command dinit will execute as part of system shutdown.
|
|
|
- If you want to install Dinit alongside another init system with its own shutdown/halt/reboot
|
|
|
- commands, set this (for eg. to "dinit-").
|
|
|
USE_UTMPX=1|0
|
|
|
Whether to build support for manipulating the utmp/utmpx database via the related POSIX
|
|
|
functions. This may be required (along with appropriate service configuration) for utilities
|